The Isolation Condenser (IC) or Isolation Condenser System is one of the injection systems in some nuclear plants (boiling water reactor safety systems).

Emergency passive system

edit

It is a passive system for cooling of some reactors (BWR/2, BWR/3 ..., and the (E)SBWR series) in nuclear production, located above containment in a pool of water open to atmosphere.

In operation, decay heat boils steam, which is drawn into the heat exchanger and condensed; then it falls by weight of gravity back into the reactor. This process keeps the cooling water in the reactor, making it unnecessary to use powered feedwater pumps. The water in the open pool slowly boils off, venting clean steam to the atmosphere. This makes it unnecessary to run mechanical systems to remove heat. Periodically, the pool must be refilled, a simple task for a fire truck. The (E)SBWR reactors provide three days' supply of water in the pool.[1] Some older reactors also have IC systems, including Fukushima Dai-ichi reactor 1, however their water pools may not be as large.

Under normal conditions, the IC system is not activated, but the top of the IC condenser is connected to the reactor's steam lines through an open valve. Steam enters the IC condenser and condenses until it is filled with water. When the IC system is activated, a valve at the bottom of the IC condenser is opened which connects to a lower area on the reactor. The water falls to the reactor via gravity, allowing the condenser to fill with steam, which then condenses. This cycle runs continuously until the bottom valve is closed.[2]

Problems

edit

In case of electricity failure, the valves close automatically, and operators have to open them manually, which can be difficult in case an accident has already released radioactive steam inside the building.

During the accident at the Fukushima nuclear plant in 2011, the operators did not open the valve manually, and the emergency system was activated too late and could not work for long. Operators did not know if they should have left the valves open or not when the tanks of two condensers were emptied of their water cooling.[3]

References

edit
  1. ^ "Status report 100 - Economic Simplified Boiling Water Reactor (ESBWR)". Washington, DC: International Atomic Energy Agency. 2011. Retrieved 2011-06-30.{{cite web}}: CS1 maint: deprecated archival service (link)
  2. ^ David Lochbaum (2011-05-24). "Fukushima Dai-Ichi Unit 1: The First 30 Minutes" (PDF). Washington, DC: Union of Concerned Scientists. Archived from the original (PDF) on 2011-05-26. Retrieved 2011-06-30.
  3. ^ Arte TV (2013) : « Fukushima, chronique d'un désastre » 2013-03-07

Bibliography

edit
edit

📚 Artikel Terkait di Wikipedia

Boiling water reactor safety systems

the (E)SBWR series of reactors, have a passive system called the Isolation Condenser. This is a heat exchanger located above containment in a pool of

Condenser

steam-electric power stations to condense turbine exhaust steam into water Isolation condenser, an emergency passive system for cooling in some reactors (BWR/2

Fukushima nuclear accident

generators. The isolation condenser (IC) system involved a closed coolant loop from the pressure vessel with a heat exchanger in a dedicated condenser tank. Steam

Fukushima nuclear accident (Unit 1 Reactor)

hit—around 19:00-20:00 JST on March 11, 2011—due to the failure of the isolation condenser. This is earlier than some initial estimates by the Tokyo Electric

Economic Simplified Boiling Water Reactor

decay) from the reactor to pools of water outside containment – the Isolation Condenser System, the Gravity Driven Cooling System, and the Passive Containment

GE BWR

first BWR design with internal steam separation. It also had an isolation condenser, and pressure suppression containment. BWR Type 2 (BWR-2, BWR/2):

Boiling water reactor

bring the reaction to a near-complete stop. Another example was the Isolation Condenser system, which relied on the principle of hot water/steam rising to

Ic

of the 水 ideograph Interchangeable core, a type of lock cylinder Isolation condenser, a passive cooling system for boiling water nuclear reactors -ić