Mass attenuation coefficients of selected isotopes for X-ray photons with energies up to 250 keV.

The mass attenuation coefficient, or mass narrow beam attenuation coefficient of a material is the attenuation coefficient normalized by the density of the material; that is, the attenuation per unit mass (rather than per unit of distance). Thus, it characterizes how easily a mass of material can be penetrated by a beam of light, sound, particles, or other energy or matter.[1] In addition to visible light, mass attenuation coefficients can be defined for other electromagnetic radiation (such as X-rays), sound, or any other beam that can be attenuated. The SI unit of mass attenuation coefficient is the square metre per kilogram (m2/kg). Other common units include cm2/g (the most common unit for X-ray mass attenuation coefficients) and Lโ‹…gโˆ’1โ‹…cmโˆ’1 (sometimes used in solution chemistry). Mass extinction coefficient is an old term for this quantity.[1]

The mass attenuation coefficient can be thought of as a variant of absorption cross section where the effective area is defined per unit mass instead of per particle.

Mathematical definitions

edit

The mass attenuation coefficient is defined as where

When using the mass attenuation coefficient, the Beerโ€“Lambert law is written in alternative form as where is the area density, also known as mass thickness, and is the length over which the attenuation takes place.

Mass absorption and scattering coefficients

edit

When a narrow (collimated) beam passes through a volume, the beam will lose intensity to two processes: absorption and scattering.

The mass absorption coefficient and mass scattering coefficient are defined as where

  • ฮผa is the absorption coefficient;
  • ฮผs is the scattering coefficient.

In solutions

edit

In chemistry, mass attenuation coefficients are often used for a chemical species dissolved in a solution. In that case, the mass attenuation coefficient is defined by the same equation, except that the "density" is the density of only that one chemical species, and the "attenuation" is the attenuation due to only that one chemical species. The actual attenuation coefficient is computed by where each term in the sum is the mass attenuation coefficient and density of a different component of the solution (the solvent must also be included). This is a convenient concept because the mass attenuation coefficient of a species is approximately independent of its concentration (as long as certain assumptions are fulfilled).

A closely related concept is molar absorptivity. They are quantitatively related by

(mass attenuation coefficient) ร— (molar mass) = (molar absorptivity).

X-rays

edit
Mass attenuation coefficient of iron with contributing sources of attenuation: coherent scattering, incoherent scattering, photoelectric absorption, and two types of pair production. The discontinuity of photoelectric absorption values are due to K-edge. Graph data came from NIST's XCOM database.
Mass attenuation coefficient values shown for all elements with atomic number Z smaller than 100 collected for photons with energies from 1 keV to 20 MeV. The discontinuities in the values are due to absorption edges which were also shown.

Tables of photon mass attenuation coefficients are essential in radiological physics, radiography (for medical and security purposes), dosimetry, diffraction, interferometry, crystallography, and other branches of physics. The photons can be in form of X-rays, gamma rays, and bremsstrahlung.

The values of mass attenuation coefficients, based on proper values of photon cross section, are dependent upon the absorption and scattering of the incident radiation caused by several different mechanisms such as

The actual values have been thoroughly examined and are available to the general public through three databases run by National Institute of Standards and Technology (NIST):

  1. XAAMDI database;[2]
  2. XCOM database;[3]
  3. FFAST database.[4]

Calculating the composition of a solution

edit

If several known chemicals are dissolved in a single solution, the concentrations of each can be calculated using a light absorption analysis. First, the mass attenuation coefficients of each individual solute or solvent, ideally across a broad spectrum of wavelengths, must be measured or looked up. Second, the attenuation coefficient of the actual solution must be measured. Finally, using the formula

the spectrum can be fitted using ฯ1, ฯ2, โ€ฆ as adjustable parameters, since ฮผ and each ฮผ/ฯi are functions of wavelength. If there are N solutes or solvents, this procedure requires at least N measured wavelengths to create a solvable system of simultaneous equations, although using more wavelengths gives more reliable data.

See also

edit

References

edit
  1. ^ a b IUPAC, Compendium of Chemical Terminology, 5th ed. (the "Gold Book") (2025). Online version: (2006โ€“) "Attenuation coefficient".doi:10.1351/goldbook.A00516
  2. ^ Hubbell, J. H.; Seltzer, S. M. "Tables of X-Ray Mass Attenuation Coefficients and Mass Energy-Absorption Coefficients". National Institute of Standards and Technology (NIST). Retrieved 2 Nov 2007.
  3. ^ M.J.Berger; J.H. Hubbell; S.M. Seltzer; J. Chang; J.S. Coursey; R. Sukumar; D.S. Zucker. "XCOM: Photon Cross Sections Database". National Institute of Standards and Technology (NIST). Retrieved 2 Nov 2007.
  4. ^ Chantler, C.T.; Olsen, K.; Dragoset, R.A.; Chang, J.; Kishore, A.R.; Kotochigova, S.A.; Zucker, D.S. "X-Ray Form Factor, Attenuation and Scattering Tables (version 2.1)". National Institute of Standards and Technology (NIST). Retrieved 2 Nov 2007.

๐Ÿ“š Artikel Terkait di Wikipedia

Molar absorption coefficient

In chemistry, the molar absorption coefficient or molar attenuation coefficient (ฮต) is a measurement of how strongly a chemical species absorbs, and thereby

Attenuation coefficient

is thus ฮผ = n ฯƒ. The mass attenuation coefficient, mass absorption coefficient, and mass scattering coefficient are defined as ฮผ ฯ m , ฮผ a ฯ m , ฮผ s ฯ

Absorption cross section

particle and its energy, the absorption cross section of the target material can be calculated from mass absorption coefficient using: ฯƒ = ( ฮผ / ฯ ) m a /

Planck's law

a "mass absorption coefficient" ฮบฮฝ = โ ฮฑ/ฯโ  which is a property of the material itself. The change in intensity of a light beam due to absorption as it

Absorption (electromagnetic radiation)

The mass attenuation coefficient (also called "mass extinction coefficient"), which is the absorption coefficient divided by density The absorption cross

Extinction coefficient

Extinction coefficient refers to several different measures of the absorption of light in a medium: Attenuation coefficient, sometimes called "extinction

Absorption (acoustics)

calculate the random-incidence absorption coefficient. This method yields the practical sound absorption coefficient, which may exceed 1.0 due to edge

X-ray filter

dependent on the material's mass absorption coefficient and tends to decrease for incident photons of greater energy. True absorption occurs when X-rays of